Spesification : |
ECG Leads | : | 10 lead 12 channel simulataneous 10-second resting ECG |
Dimension | : | 296 (w) x 305.5 (h) x 92.5 (d) mm |
| : | Approximately 2.98 kg |
Recording Channel | : | 3,6,12 channel and 1 channel (60 sec) |
Sensitivity | : | 5, 10, 20 auto (I~aVF: 10, V1~V6:5) mm/mV |
Printing Speed | : | 12.5, 25, 50 mm/s |
Filters | : | AC (50/60 Hz, -20dB or better) |
| : | Muscle (25~35Hz, -3dB or better) |
| : | Base Line Drift (0.1Hz, -3dB or better) |
| : | Low pass filter (off, 40Hz, 100Hz, 150Hz) |
Display | : | 2 x 16 character LCD display |
LCD display | : | Sensitivity, speed, filter status, HR, printing form, rhythm lead |
LED indicator | : | Signal quality, power source, battery |
Keyboard | : | Membrane keyboard |
| : | Alphanumeric and symbol available |
Patient Data | : | ID, name, age, sex, height, weight |
Basic Measurement | : | Heart rate, PR, QRS, QT/QTc, P-R-T axis |
Recorder | : | Thermal print head, thermal roll paper |
| : | Report papers: |
| : | - Width: A4: 210mm or 8.5" |
| : | - Length: A4: 300mm or 11" |
| : | Effective writing width: 204mm |
| : | Resolution: |
| : | - Vertical: 8 dots/mm |
| : | - Horizontal: 16 dots/mm |
Electrical | : | Internal noise: 20uV(p-p) max |
| : | Input circuit: Floating input |
| : | Isolated and defibrillation protected |
| : | Input impedance: >10MQ |
| : | Input range: > +/- 5mV |
| : | Common Mode Rejection: > +100dB |
| : | DC offset voltage: > +/- 300mV |
| : | Time constant: 3.2 sec |
| : | Patient leakage current: <10ua |
| : | Frequency response: 0.05~150Hz |
Signal qualilty control | : | Disconnected lead detection |
Power | : | Power Supply: AC or built-in Battery (option) |
| : | Power requirement: 100 - 240 Vac, 50/60Hz, 1.0 - 0.5A |
| : | Power consumption: 60w max |
Battery capacity | : | 1 hour of normal use (approximately 100 automatic ECG printouts) |
Communication | : | PC connection with RS-232 interface and LAN |
Safety | : | Class 1, Type BF |
Conformity | : | CE, CSA |
Environment | : | Operating humidity: 30~85% |
| : | Operating temperature: 10° ~40° C |
| : | Atmospheric pressure: 70 ~ 106 KPa |
Standard accessory | : | Power Cable - 1 ea. |
| : | Patient Cable - 1 ea. |
| : | Electrode - 10 ea. |
| : | Chart Paper - 1 ea. |
| : | Operation Manual - 1 ea. |
Options | : | Rechargeable Battery (ni-mh) |
| : | Cart |
| : | Hanger |
| : | Bag |
| : | PC s/w |
| : | Limb electrode |
| : | Chest electrode |
| : | RS-232C null cable |
| : | LAN cable (Ethernet-RJ-45) |
| | |